Registered users receive a variety of benefits including the ability to customize email alerts, create favorite journals list, and save searches.
Please note that a BioOne web account does not automatically grant access to full-text content. An institutional or society member subscription is required to view non-Open Access content.
Contact helpdesk@bioone.org with any questions.
K. Rothkamm, C. Beinke, H. Romm, C. Badie, Y. Balagurunathan, S. Barnard, N. Bernard, H. Boulay-Greene, M. Brengues, A. De Amicis, S. De Sanctis, R. Greither, F. Herodin, A. Jones, S. Kabacik, T. Knie, U. Kulka, F. Lista, P. Martigne, A. Missel, J. Moquet, U. Oestreicher, A. Peinnequin, T. Poyot, U. Roessler, H. Scherthan, B. Terbrueggen, H. Thierens, M. Valente, A. Vral, F. Zenhausern, V. Meineke, H. Braselmann, M. Abend
Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3–0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5–4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools.
H. Romm, S. Barnard, H. Boulay-Greene, A. De Amicis, S. De Sanctis, M. Franco, F. Herodin, A. Jones, U. Kulka, F. Lista, P. Martigne, J. Moquet, U. Oestreicher, K. Rothkamm, H. Thierens, M. Valente, V. Vandersickel, A. Vral, H. Braselmann, V. Meineke, M. Abend, C. Beinke
The focus of the study is an intercomparison of laboratories' dose-assessment performances using the cytokinesis-block micronucleus (CBMN) assay as a diagnostic triage tool for individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25–5 Gy) as well as blind samples (0.1–6.4 Gy) were sent to the participants. The CBMN assay was performed according to protocols individually established and varying among participating laboratories. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) was calculated and radiation doses were merged into four triage categories reflecting clinical aspects to calculate accuracy, sensitivity and specificity. The earliest report time was 4 days after sample arrival. The CBMN dose estimates were reported with high accuracy (MAD values of 0.20–0.50 Gy at doses below 6.4 Gy for both manual and automated scoring procedures), but showed a limitation of the assay at the dose point of 6.4 Gy, which resulted in a clear dose underestimation in all cases. The MAD values (without 6.4 Gy) differed significantly (P = 0.03) between manual (0.25 Gy, SEM = 0.06, n = 4) or automated scoring procedures (0.37 Gy, SEM = 0.08, n = 5), but lowest MAD were equal (0.2 Gy) for both scoring procedures. Likewise, both scoring procedures led to the same allocation of dose estimates to triage categories of clinical significance (about 83% accuracy and up to 100% specificity).
C. Beinke, S. Barnard, H. Boulay-Greene, A. De Amicis, S. De Sanctis, F. Herodin, A. Jones, U. Kulka, F. Lista, D. Lloyd, P. Martigne, J. Moquet, U. Oestreicher, H. Romm, K. Rothkamm, M. Valente, V. Meineke, H. Braselmann, M. Abend
The study design and obtained results represent an intercomparison of various laboratories performing dose assessment using the dicentric chromosome analysis (DCA) as a diagnostic triage tool for individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25–5 Gy) as well as blind samples (0.1–6.4 Gy) were sent to the participants. DCA was performed according to established protocols. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) was calculated and radiation doses were merged into four triage categories reflecting clinical aspects to calculate accuracy, sensitivity and specificity. The earliest report time was 2.4 days after sample arrival. DCA dose estimates were reported with high and comparable accuracy, with MAD values ranging between 0.16–0.5 Gy for both manual and automated scoring. No significant differences were found for dose estimates based either on 20, 30, 40 or 50 cells, suggesting that the scored number of cells can be reduced from 50 to 20 without loss of precision of triage dose estimates, at least for homogenous exposure scenarios. Triage categories of clinical significance could be discriminated efficiently using both scoring procedures.
C. Badie, S. Kabacik, Y. Balagurunathan, N. Bernard, M. Brengues, G. Faggioni, R. Greither, F. Lista, A. Peinnequin, T. Poyot, F. Herodin, A. Missel, B. Terbrueggen, F. Zenhausern, K. Rothkamm, V. Meineke, H. Braselmann, C. Beinke, M. Abend
The possibility of a large-scale acute radiation exposure necessitates the development of new methods that could provide rapid individual dose estimates with high sample throughput. The focus of the study was an intercomparison of laboratories' dose-assessment performances using gene expression assays. Lithium-heparinized whole blood from one healthy donor was irradiated (240 kVp, 1 Gy/min) immediately after venipuncture at approximately 37°C using single X-ray doses. Blood samples to establish calibration curves (0.25–4 Gy) as well as 10 blinded test samples (0.1–6.4 Gy) were incubated for 24 h at 37°C supplemented with an equal volume of medium and 10% fetal calf serum. For quantitative reverse transcription polymerase chain reaction (qRT-PCR), samples were lysed, stored at −20°C and shipped on ice. For the Chemical Ligation Dependent Probe Amplification methodology (CLPA), aliquots were incubated in 2 ml CLPA reaction buffer (DxTerity), mixed and shipped at room temperature. Assays were run in each laboratory according to locally established protocols. The mean absolute difference (MAD) of estimated doses relative to the true doses (in Gy) was calculated. We also merged doses into binary categories reflecting aspects of clinical/diagnostic relevance and examined accuracy, sensitivity and specificity. The earliest reported time on dose estimates was <8 h. The standard deviation of technical replicate measurements in 75% of all measurements was below 11%. MAD values of 0.3–0.5 Gy and 0.8–1.3 Gy divided the laboratories contributions into two groups. These fourfold differences in accuracy could be primarily explained by unexpected variances of the housekeeping gene (P = 0.0008) and performance differences in processing of calibration and blinded test samples by half of the contributing laboratories. Reported gene expression dose estimates aggregated into binary categories in general showed an accuracies and sensitivities of 93–100% and 76–100% for the groups, with low MAD and high MAD, respectively. In conclusion, gene expression-based dose estimates were reported quickly, and for laboratories with MAD between 0.3–0.5 Gy binary dose categories of clinical significance could be discriminated with an accuracy and sensitivity comparable to established cytogenetic assays.
The focus of the study is an intercomparison of laboratories' dose-assessment performances using the γ-H2AX foci assay as a diagnostic triage tool for rapid individual radiation dose assessment. Homogenously X-irradiated (240 kVp, 1 Gy/min) blood samples for establishing calibration data (0.25–4 Gy) as well as blinded test samples (0.1–6.4 Gy) were incubated at 37°C for 2 and 24 h (repair time) and sent to the participants. The foci assay was performed according to protocols individually established in participating laboratories and therefore varied. The time taken to report dose estimates was documented for each laboratory. Additional information concerning laboratory organization/characteristics as well as assay performance was collected. The mean absolute difference (MAD) of estimated doses relative to the actual doses was calculated and radiation doses were merged into four triage categories reflecting clinical relevance to calculate accuracy, sensitivity and specificity. First γ-H2AX based dose estimates were reported 7 h after sample receipt. Estimates were similarly accurate for 2 and 24 h repair times, providing scope for its use in the early phase of a radiation exposure incident. Equal accuracy was achieved by scoring 20, 30, 40 or 50 cells per sample. However, MAD values of 0.5–0.7 Gy and 1.3–1.7 Gy divided the data sets into two groups, driven mainly by the considerable differences in foci yields between calibration and blind samples. Foci yields also varied dramatically between laboratories, highlighting reproducibility issues as an important caveat of the foci assay. Nonetheless, foci counts could distinguish high- and low-dose samples in all data sets and binary dose categories of clinical significance could be discriminated with satisfactory accuracy (mean 84%, ±0.03 SEM). Overall, the results suggest that the γ-H2AX assay is a useful tool for rapidly screening individuals for significant exposures that occurred up to at least 24 h earlier, and may help to prioritize cytogenetic dosimetry follow-up.
James A. Jacobus, Chester G. Duda, Mitchell C. Coleman, Sean M. Martin, Kranti Mapuskar, Gaowei Mao, Brian J. Smith, Nukhet Aykin-Burns, Peter Guida, David Gius, Frederick E. Domann, C. Michael Knudson, Douglas R. Spitz
The hypothesis that mitochondrial dysfunction and increased superoxide levels in thymocytes over expressing Bax (Lck-Bax1 and Lck-Bax38&1) contributes to lymphomagenesis after low-dose radiation was tested. Lck-Bax1 single-transgenic and Lck-Bax38&1 double-transgenic mice were exposed to single whole-body doses of 10 or 100 cGy of 137Cs or iron ions (1,000 MeV/n, 150 keV/μm) or silicon ions (300 MeV/n, 67 keV/μm). A 10 cGy dose of 137Cs significantly increased the incidence and onset of thymic lymphomas in female Lck-Bax1 mice. In Lck-Bax38&1 mice, a 100 cGy dose of high-LET iron ions caused a significant dose dependent acceleration of lymphomagenesis in both males and females that was not seen with silicon ions. To determine the contribution of mitochondrial oxidative metabolism, Lck-Bax38&1 over expressing mice were crossed with knockouts of the mitochondrial protein deacetylase, Sirtuin 3 (Sirt3), which regulates superoxide metabolism. Sirt3–/–/Lck-Bax38&1 mice demonstrated significant increases in thymocyte superoxide levels and acceleration of lymphomagenesis (P < 0.001). These results show that lymphomagenesis in Bax over expressing animals is enhanced by radiation exposure in both an LET and gender dependent fashion. These findings support the hypothesis that mitochondrial dysfunction leads to increased superoxide levels and accelerates lymphomagenesis in Lck-Bax transgenic mice.
The effectiveness of simulated solar particle event (SPE) proton radiation to induce retching and vomiting was evaluated in the ferret experimental animal model. The endpoints measured in the study included: (1) the fraction of animals that retched or vomited, (2) the number of retches or vomits observed, (3) the latency period before the first retch or vomit and (4) the duration between the first and last retching or vomiting events. The results demonstrated that γ ray and proton irradiation delivered at a high dose rate of 0.5 Gy/min induced dose-dependent changes in the endpoints related to retching and vomiting. The minimum radiation doses required to induce statistically significant changes in retching- and vomiting-related endpoints were 0.75 and 1.0 Gy, respectively, and the relative biological effectiveness (RBE) of proton radiation at the high dose rate did not significantly differ from 1. Similar but less consistent and smaller changes in the retching- and vomiting-related endpoints were observed for groups irradiated with γ rays and protons delivered at a low dose rate of 0.5 Gy/h. Since this low dose rate is similar to a radiation dose rate expected during a SPE, these results suggest that the risk of SPE radiation-induced vomiting is low and may reach statistical significance only when the radiation dose reaches 1 Gy or higher.
Astronauts have the potential to develop the hematopoietic syndrome as a result of exposure to radiation from a solar particle event (SPE) during exploration class missions. This syndrome is characterized by a reduction in the number of circulating blood cells (cytopenias). In the present study the effects of SPE-like proton and γ radiation on the kinetics of circulating neutrophils were evaluated during a one-month time period using mice as a model system. The results revealed that exposure to a 2 Gy dose of either SPE-like proton or γ radiation significantly decreased the number of circulating neutrophils, with two nadirs observed on day 4 and day 16 postirradiation. Low circulating neutrophil count (neutropenia) is particularly important because it can increase the risk of astronauts developing infections, which can compromise the success of the mission. Thus, two granulocyte colony-stimulating factors (G-CSFs), filgrastim and pegfilgrastim were evaluated as countermeasures for this endpoint. Both forms of G-CSF significantly increased neutrophil counts in irradiated mice, however, the effect of pegfilgrastim was more potent and lasted longer than filgrastim. Using the expression of CD11b, CD18 and the production of reactive oxygen species (ROS) as markers of neutrophil activation, it was determined that the neutrophils in the irradiated mice treated with pegfilgrastim were physiologically active. Thus, these results suggest that pegfilgrastim could be a potential countermeasure for the reduced number of circulating neutrophils in irradiated animals.
Michael W. Epperly, J. Richard Chaillet, Ronny Kalash, Ben Shaffer, Julie Goff, Darcy Franicola, Xichen Zhang, Tracy Dixon, Frank Houghton, Hong Wang, Hebist Berhane, Cynthia Romero, Jee-Hong Kim, Joel S. Greenberger
Mitochondrial targeted manganese superoxide dismutase is a major antioxidant enzyme, the levels of which modulate the response of cells, tissues and organs to ionizing irradiation. We developed a Tet-regulated MnSOD mouse (MnSODtet) to examine the detailed relationship between cellular MnSOD concentration and radioresistance and carried out in vitro studies using bone marrow culture derived stromal cell lines (mesenchymal stem cells). Homozygous MnSODtet/tet cells had low levels of MnSOD, reduced viability and proliferation, increased radiosensitivity, elevated overall antioxidant stores, and defects in cell proliferation and DNA strand-break repair. Doxycycline (doxy) treatment of MnSODtet/tet cells increased MnSOD levels and radioresistance from ñ of 2.79 ± 1.04 to 8.69 ± 1.09 (P = 0.0060) and normalized other biologic parameters. In contrast, MnSODtet/tet cells showed minimal difference in baseline and radiation induced mRNA and protein levels of TGF-β, Nrf2 and NF-κB and radiation induced cell cycle arrest was not dependent upon MnSOD level. These novel MnSODtet/tet mouse derived cells should be valuable for elucidating several parameters of the oxidative stress response to ionizing radiation.
Radiation induced fibrosis of the skin is a late toxicity that may result in loss of function due to reduced range of motion and pain. The current study sought to determine if oral delivery of quercetin mitigates radiation-induced cutaneous injury. Female C3H/HeN mice were fed control chow or quercetin-formulated chow (1% by weight). The right hind leg was exposed to 35 Gy of X rays and the mice were followed serially to assess acute toxicity and hind leg extension. Tissue samples were collected for assessment of soluble collagen and tissue cytokines. Human and murine fibroblasts were subjected to clonogenic assays to determine the effects of quercetin on radiation response. Contractility of fibroblasts was assessed with a collagen contraction assay in the presence or absence of quercetin and transforming growth factor-β (TGF-β). Western blotting of proteins involved in fibroblast contractility and TGF-β signaling were performed. Quercetin treatment significantly reduced hind limb contracture, collagen accumulation and expression of TGF-β in irradiated skin. Quercetin had no effect on the radioresponse of fibroblasts or murine tumors, but was capable of reducing the contractility of fibroblasts in response to TGF-β, an effect that correlated with partial stabilization of phosphorylated cofilin. Quercetin is capable of mitigating radiation induced skin fibrosis and should be further explored as a therapy for radiation fibrosis.
The role of mast cell infiltrates in the pathology of radiation damage to the lung has been a subject of continuing investigation over the past four decades. This has been accompanied by a number of proposals as to how mast cells and the secretory products thereof participate in the generation of acute inflammation (pneumonitis) and the chronic process of collagen deposition (fibrosis). An additional pathophysiology examines the possible connection between mast cell hyperplasia and pulmonary hypertension through the release of vasoactive mediators. The timing and magnitude of pneumonitis and fibrosis are known to vary tremendously among different genetic mouse strains and animal species. Therefore, we have systematically compared mast cell numbers in lung sections from nine mouse strains, two rat strains and nonhuman primates (NHP) after whole thorax irradiation (WTI) at doses ranging from 10–15 Gy and at the time of entering respiratory distress. Mice of the BALB/c strain had a dramatic increase in interstitial mast cell numbers, similar to WAG/Rij and August rats, while relatively low levels of mast cell infiltrate were observed in other mouse strains (CBA, C3H, B6, C57L, WHT and TO mice). Enumeration of mast cell number in five NHPs (rhesus macaque), exhibiting severe pneumonitis at 17 weeks after 10 Gy WTI, also indicated a low response shared by the majority of mouse strains. There appeared to be no relationship between the mast cell response and the strain-dependent susceptibility towards pneumonitis or fibrosis. Further investigations are required to explore the possible participation of mast cells in mediating specific vascular responses and whether a genetically diverse mast cell response occurs in humans.
This article is only available to subscribers. It is not available for individual sale.
Access to the requested content is limited to institutions that have
purchased or subscribe to this BioOne eBook Collection. You are receiving
this notice because your organization may not have this eBook access.*
*Shibboleth/Open Athens users-please
sign in
to access your institution's subscriptions.
Additional information about institution subscriptions can be foundhere