BioOne.org will be down briefly for maintenance on 17 December 2024 between 18:00-22:00 Pacific Time US. We apologize for any inconvenience.
How to translate text using browser tools
1 June 2012 THORACIC AUSCULTATION IN CAPTIVE BOTTLENOSE DOLPHINS (TURSIOPS TRUNCATUS), CALIFORNIA SEA LIONS (ZALOPHUS CALIFORNIANUS), AND SOUTH AFRICAN FUR SEALS (ARCTOCEPHALUS PUSILLUS) WITH AN ELECTRONIC STETHOSCOPE
Julia Scharpegge, Manuel García Hartmann, Klaus Eulenberger
Author Affiliations +
Abstract

Thoracic auscultation is an important diagnostic method used in cases of suspected pulmonary disease in many species, as respiratory sounds contain significant information on the physiology and pathology of the lungs and upper airways. Respiratory diseases are frequent in marine mammals and are often listed as one of their main causes of death. The aim of this study was to investigate and report baseline parameters for the electronic-mediated thoracic auscultation of one cetacean species and two pinniped species in captivity. Respiratory sounds from 20 captive bottlenose dolphins (Tursiops truncatus), 6 California sea lions (Zalophus californianus), and 5 South African fur seals (Arctocephalus pusillus) were recorded with an electronic stethoscope. The sounds were analyzed for duration of the respiratory cycle, adventitious sounds, and peak frequencies of recorded sounds during expiration and inspiration as well as for sound intensity as reflected by waveform amplitude during the respiratory cycle. In respiratory cycles of the bottlenose dolphins' expiring “on command,” the duration of the expiration was significantly shorter than the duration of the inspiration. In the examined pinnipeds of this study, there was no clear pattern concerning the duration of one breathing phase: Adventitious sounds were detected most often in bottlenose dolphins that were expiring on command and could be compared with “forced expiratory wheezes” in humans. This is the first report of forced expiratory wheezes in bottlenose dolphins; they can easily be misinterpreted as pathologic respiratory sounds. The peak frequencies of the respiratory sounds reached over 2,000 Hz in bottlenose dolphins and over 1,000 Hz in California sea lions and South African fur seals, but the variation of the frequency spectra was very high in all animals. To the authors' knowledge, this is the first systematic analysis of respiratory sounds of bottlenose dolphins and two species of pinnipeds.

American Association of Zoo Veterinarians
Julia Scharpegge, Manuel García Hartmann, and Klaus Eulenberger "THORACIC AUSCULTATION IN CAPTIVE BOTTLENOSE DOLPHINS (TURSIOPS TRUNCATUS), CALIFORNIA SEA LIONS (ZALOPHUS CALIFORNIANUS), AND SOUTH AFRICAN FUR SEALS (ARCTOCEPHALUS PUSILLUS) WITH AN ELECTRONIC STETHOSCOPE," Journal of Zoo and Wildlife Medicine 43(2), 265-274, (1 June 2012). https://doi.org/10.1638/2011-0022.1
Received: 14 February 2011; Published: 1 June 2012
KEYWORDS
Arctocephalus pusillus
Bottlenose dolphin
California sea lion
electronic stethoscope
forced expiratory wheeze
respiratory sounds
South African fur seal
RIGHTS & PERMISSIONS
Get copyright permission
Back to Top